If hayward heater code

Page 24: Heater Not Firing 5. Heater Not Firing The ProLogic features a normally open circuit for each heater. When heat is called for, based on the temp set point and water sensor, the low voltage contact will close; once closed, the low voltage supplied by the heater should be returned to it. Page 25 5. Heater Not Firing (cont.) Service mode ...

If hayward heater code. Aug 12, 2019 ... Hayward Pool Heater Sb Error Code 56 EASY FIX Stuck Button ... Pool Basics: How To Start/Light a Hayward H-Series Pool Heater ... Be Careful When ...

What Causes the 1F Error Code? The 1F error code on a Hayward pool heater typically indicates a problem with the heater's control panel or circuit board.

Hayward Pool Heater Lo Code Troubleshoot And Diagnosis. You should only hire a professional to do Hayward pool heater troubleshooting if you have no idea how to or dont have the time to do it yourself. Hiring an expert is always the best way to keep your pool heater in top condition and avoid any major problems from happening.FAQ’s. What does the Hayward heater IF code mean? How Do I Fix the Hayward heater IF code? Can I fix the IF code myself, or …To avoid encountering the Hayward Heater LO Code in the future, consider implementing these preventive measures: Regular Maintenance: Stay on top of regular maintenance tasks, such as cleaning or replacing your pool filter and inspecting your plumbing system for blockages.Jan 1, 2024 · Common Causes of the H5 Code. When your pool heater displays the H5 code, it typically occurs due to a few common reasons. Troubleshooting h5 code in other pool equipment can help identify the issue. Common misconceptions about h5 code in Hayward pool heaters include thinking it is solely related to a faulty igniter or gas valve. Hayward H250FDP pool heater showed SF code. Replaced the thermistor and restarted the power. Display still shows SF code and sevice light on. Cycled the mode button and the blower comes on, but no ign … read moreIt. The Hayward H-Series H250FDN is extremely reliable and energy efficient. It marries high performance with environmentally responsible low NOx emissions and can provide energy savings of up to 18% compared to other similar pool heaters. Purchased in Sept. 2016, had to replace the heat exchanger once, but we wer.Hayward products including, quick reference guides, troubleshooting steps, and product support videos. ... Heater required kW : Heater required BTU/hr : Water weight kg : Water weight Lbs : ... Scan the QR code to send us a quick information request. Include your phone/messaging contact number and country in your message.The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.

Savings: $17.00. Add To Cart. Hayward FDXLTER1930 Thermistor Fits Universal H-Series. FDXLTER1930 Fits Hayward universal H-series low nox pool heater models. Our Price: $52.00. Sale Price: $41.00. Savings: $11.00. Add To Cart. Hayward FDXLTER1931 Thermistor Fits New Universal H-Series.Home - Trouble Free Pool | Trouble Free PoolHeater Hayward ED2 Fault Code Thumbnails (18 pages) Summary of Contents for Hayward H150FDAU. Page 1 POOL AND SPA/HOT TUB HEATERS H150FDAU, ... LEASE n order to insure a longer life for your new Hayward Pool Heater as well as your liner (if applicable), pump and fi lter, HELPFUL HINTS steps should be taken to insure proper water chemistry. The ...Do you want to learn how to fix a pool heater with a p5 error? Watch this video to see how a pressure valve can solve the problem. You will also find tips and tricks for pool maintenance and ...Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 25 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 165 lb: Product Width:Hayward H400FD Manuals. Manuals and User Guides for Hayward H400FD. We have 13 Hayward H400FD manuals available for free PDF download: Service & Installation Manual, Manuel D'entretien Et D'installation, Owner's Manual, Quick Manual, Quick Reference Manual.Dealing with the Hayward Heater HS IO code can be challenging, but with the right knowledge, preventive measures, and a willingness to explore advanced options, you can maintain a reliable and safe heating system for your pool or spa. Remember that safety should always be a top priority when working with gas appliances, and don't hesitate to ...

Here you’ll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place. ... iPad Heater Navigation - OmniLogic Automation System. iPhone Favorites - OmniLogic ...1. First, check that your filter pump is On. Next, ensure the heater is enabled and the set point is higher than the current water temperature. Select the bow to water. Press the heater tile to enter the heater's menu. 2. Ensure the heater is enabled and the set point is higher than the current water temperature.Aug 28, 2021 ... Comments16 · How to Repair Pentair Master Temp Error E05 or E06 · Pool heater not heating the water, making popping sounds. · Hayward H400FD p...The Lo on a Hayward heater means “low.” When the Lo setting is selected, the heater runs at a lower speed, which can help conserve energy. In some cases, the Lo setting may indicate a malfunction or another issue with the heater. If you notice your Hayward heater displaying an LO code, it is important to check the manual or contact …

Hiset reading test.

>The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. ... South Coast Quality Air Management Commission for 2001 and the Texas Natural Resource Conservation Commission Code. Superior Hydraulic Performance - New polymer header provides superior hydraulic performance to save ...Hayward pool heaters are equipped with a self-diagnostic system that detects faults and shuts the unit down. If your pool heater is displaying a code, follow these steps to reset the unit: 1. Turn the power off to the pool heater at the breaker box. 2. Wait five minutes and then turn the power back on. 3.Learn How Solar Pool Heaters Work; Learn About Hayward. At Hayward, we're more than just equipment. Learn more. Hayward Insights. Hayward Insights. Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support.Attachment IV Reach Code for Part 11 (California Green Building Standards Code) CITY OF HAYWARD Page 1 of 1 Printed on 9/13/2019 ... traditional electric resistance heaters, do not generate heat, but concentrate and transfer it for end uses such as space conditioning/heating and water heating. This process uses lessGAS HEATERS: Universal H-series ASME Heater: 3 Years: CHLORINE GENERATOR & UVO3 SYSTEMS: Saline C ® 6.0 & 11.0 Salt Chlorine Generators: 2 Years* None: 2 Years* None: 2 Years** 2 Years* *Salt cells carry an 18 month parts warranty. * No field labor, factory repair labor only. **Salt cells carry a 1 year full warranty & a prorated warranty for ...Turn off the pool heater using the power switch or breaker. Wait for at least 30 seconds to ensure the heater completely powers down. Turn the power back on and observe the display board. If the display board is functioning properly, it should show the default screen or a startup message.

Hayward - W3HP21004T HeatPro 90K BTU, 230V, Titanium, Digital, Electric Pool Heat Pump. $4,299.00. Delivery. FREE Standard Shipping On All Orders! Shop Now. Hayward pool heaters extend swimming seasons by raising the water temperature of your swimming pool. Gas pool heaters efficiently heat a pool to desired temperature.Hayward 150 heater through an AO code which often means a blower switch. This was $28 and super easy to install. Seriously, I've been more difficulty plugging Lampson to outlets and changing the switch. Seriously, I've been more difficulty plugging lamps into outlets than changing this switch.Fixed our problem for less than $30.Hayward 400 bo code. texasstig. Mar 13, 2021. bo code hayward heater failure - remote not firing heater. Jump to latest Follow Reply. Forums. Equipment - Build, Use, and Repair. Everything Else. T.Hayward H400 trouble code 5F. Our Hayword H400 pool heater won't come on this morning. Display flashes 5F. Filter is clean. Tried shutting down a few minutes and restarting but no change. Reply With Quote.You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the "bO" message should appear ...Universal H-Series Natural Gas 400,000 BTU Low NOx. Hayward. SKU: W3H400FDN. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Add to Compare. Add to Export.Heater Hayward ED2 Fault Code Thumbnails (18 pages) Heater Hayward C-SPA-XI 5.5 Installation And Operation Manual. Pool and spa/hot tub heaters (24 pages) Summary of Contents for Hayward H250FDN.When ordering parts, include the complete pool heater model number listed on the unit’s rating plate, located near the junction boxes on the exhaust side of the heater. (Example: HDF400) All ser- vice must be performed by a qualified technician. View and Download Hayward HDF400 installation & operation manual online.The following 6 California counties are affected: Los Angeles, San Bernardino, Ventura, Orange, Riverside, and Kern. Installing a non-compliant heater in these counties will void the manufacturer's warranty and could result in a fine from your local code enforcement. Item cannot be refunded/returned without approval and authorization from Home ...The SF code on your Hayward heater’s display stands for “Stack Flue Sensor Failure.”. This code indicates that there’s a problem with the sensor responsible for monitoring the flue gases in your heater. Flue gases are the byproducts of combustion, and monitoring them is crucial for safety reasons. Common Causes of SF Code.

The Hayward pool heater spa mode is designed to maintain a specific "spa-like" temperature in the pool. To use this mode, enable "Spa mode" from the control panel, set the required temperature, and let the pool heater warm the water. Once ready, test the water. This process is a joy to behold for those who want to soak themselves in ...

Remove front & rear panels Remove wires from limit switches. Step 13. Remove the 4 screws from the bottom of the front and rear panels and pull up and out to remove each one. Step 14. Use needle nose pliers to remove the 2 red wires from each of the high limit switches. Remove wires from water pressure switch.Hayward H250 pool heaters can experience ignition failure due to a variety of reasons. Possible causes include: faulty electrical connections, a failed thermistor or Hi-Limit switch, an obstructed flue vent pipe, and/or debris in the combustion chamber. If the heater fails to ignite when it is turned on, first check that power is being supplied ...Product Description. Universal H-Series 250, 000 BTU Pool and Spa Heater, Natural Gas, Low Nox. From the Manufacturer. The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa.View online or download Hayward H200FDP Troubleshooting Manual. ... Brands; Hayward Manuals; Heater; H200FDP; Hayward H200FDP Manuals. Manuals and User Guides for Hayward H200FDP. We have 1 Hayward H200FDP manual available for free PDF download: Troubleshooting Manual ... BD" Code. 34. EE" or "CE" Code. 36. IO" or "SB" Code. 38. SF" or "HS ...Hayward - W3HP21004T HeatPro 90K BTU, 230V, Titanium, Digital, Electric Pool Heat Pump. $4,299.00. Delivery. FREE Standard Shipping On All Orders! Shop Now. Hayward pool heaters extend swimming seasons by raising the water temperature of your swimming pool. Gas pool heaters efficiently heat a pool to desired temperature.Inspect the breaker for the heater and make sure it is On. The heater/heat pump is detecting a problem. Usually, the heater will display an error code on its display when sensing a problem. Some of the most common error codes are, IF – ignition failure, LO – A pressure switch problem, and AO – a vacuum switch problem.A pool heater is an essential component of any swimming pool, especially in areas where the weather can get chilly. If you own a Hayward pool heater and it breaks down, you need to...Mention this voucher and voucher code (if applicable) when scheduling your appointment. 3. Print or show this voucher to our technician upon arrival and receive this offer! ... professional water heater repair, replacement and installation. Call us 24/7/365 for reliable Hayward water heater service (510) 881-8848. We have proudly served the ...The heater attempts to light the burner three times before displaying the IF code and shutting down. The code protects the heater from damage caused by a gas buildup or other ignition-related problems. Common Causes of the Hayward Heater IF Code. There are several reasons your Hayward heater may be displaying the IF code.

Staccato c2 sro.

How to turn off closed captioning on fios.

Product Description. Universal H-Series 250, 000 BTU Pool and Spa Heater, Natural Gas, Low Nox. From the Manufacturer. The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa.What Is Hayward Pool Heater Code Ce And Why Is It Important? Hayward pool heater code ce is an important safety measure for pool owners. It ensures that the heater meets the necessary european standards and regulations, guaranteeing efficient and safe operation. Importance Of Complying With Code Ce StandardsOur comprehensive Hayward Pool Heaters error code guide will explain common issues, provide tips, and show you how to read your model's error codes. More …Universal H-Series Natural Gas 400,000 BTU Low NOx. Hayward. SKU: W3H400FDN. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Add to Compare. Add to Export.May 26, 2012 ... Cover up half the holes with tape and see if the heater lights and stays lit. If it does you have to replace the flame sensor with the new type.May 10, 2022 · Step 5: Clean the filter or remove any obstructions. Examine the position of the valves in the plumbing system. Set the water pressure switch to the desired setting. If the Hayward pool heater LO code persists, the water pressure switch must be replaced. 1 How to Read Hayward Serial Numbers and Date Codes. 1.1 Pumps, Filters, Cleaners, Heaters, Heat Pumps, some Incandescent Lighting and Accessories; 1.2 Controls, Electronic Chlorination, ColorLogic Lighting; 1.3 Heat Pumps, Heaters, Filters, Pumps August 2015 - Present; 1.4 Heat Pumps, Heaters, Filters, Pumps March 2010 - …Hayward 400 bo code. texasstig. Mar 13, 2021. bo code hayward heater failure - remote not firing heater. Jump to latest Follow Reply. Forums. Equipment - Build, Use, and Repair. Everything Else. T.Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater's efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...For people using gas water heaters, two options are offered--natural gas or propane. According to Energy Star, 15 percent of a home’s energy use is attributed to heating water. Bot...Pool heater started find when pool first opened up this spring. Turned off heater for past 2 weeks then went to start it up. The heater is stuck in standby mode and the service light is on. Pushing any of the buttons doesnt do anything. Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. ….

My summit xl 140 Hayward pool heater is displaying bo and it is not heating the pool, Model summit xl 140 just - Answered by a verified Pool and Spa Expert ... Sorry to hear the trouble with your Hayward heater. The bo code indicates it is being controlled by a remote thermostat which in your case is true since you control it from the ...Solar water heaters could help cut your utility bills. Visit HowStuffWorks to learn about solar water heaters. Advertisement Heating up water accounts for a good chunk of a home's ...Apr 4, 2020. #7. You can check the ignitor with a meter by measuring the ohms at the 2 leads coming from the ignitor. An older silicon carbide ignitor ( shiny crystalline and fragile ) will normally ohm out at 45-150 ohms. A newer silicon nitride ignitor ( Looks like a smooth dull black matchstick ) will normally ohm out at about 11-17 ohms.Have a Hayward Pool Heater. Model H250FDP. Have a code "HF" ( Flame Sensor ). Display also showing "service". - Answered by a verified Pool and Spa Expert. We use cookies to give you the best possible experience on our website. ... My Hayward 400K heater has worked intermittently for 1.5 days. It brought pool up to temp, but now, ...I have 2003-vintage H400IDL2 Low NOx heater. Pool controls are Aqualink RS6. A few years ago the temperature sensor circuit on the RS6 board failed, so I have been manually turning the heater on/off since. (Previously the heater was in BO mode for remote operation.) I just upgraded the RS6 to iAqualink with the IQ900RS kit (rev R firmware).To fix the issue of your OmniLogic losing connection, try these steps: 1) Turn off power at the breaker. 2) Turn the power back on and let the system reboot. This simple power cycle should reconnect the system to the Wi-Fi network. It may also be caused by wireless interference or a weak signal from your router.May 25, 2009 ... The blower cover on the right side of the blower has holes in it. Cover up half the holes with tape and see if the heater lights and stays lit.When it comes to hayward heaters, there are some common bd codes that you might encounter. Bd1 indicates ignition failure, which can often be resolved by cleaning the ignition assembly. Bd2 suggests water temperature sensor failure, which can occur due to a faulty sensor or connection issue. If you see bd3, it indicates high limit switch open ... If hayward heater code, Hayward heater will not heat above 86 degrees JA: I understand that your Hayward heater is not heating above 86 degrees, and our Expert will be able to help you with this issue. Is the heater displayi … read more, Hayward's serial numbers for all products, with the exception of some cleaners, controls, heat pumps and electronic chlorinators, are 17 digits long and begin …, Universal HC Series - Dual Fuel 400k BTU. Hayward. SKU: HDF400. The industry’s smallest footprint heater allows replacement of almost any heater in an existing pad with the efficient reliability of the new Universal HC Series dual-fuel technology heater from Hayward®. Add to Compare. Add to Export. Overview., Mar 16, 2018. #1. We have a Hayward H400IDL2 pool heater that ignites and runs normally at start up. After about 10 minutes it begins to repeatedly cycle off and on before finally throwing an IF code. We've had multiple service calls from 2 different pool companies and have replaced the gas valve, flame sensor, igniter and control board., Pumps, Filters, Cleaners, Heaters, Heat Pumps, some Incandescent Lighting and Accessories. Hayward's serial numbers for all products, with the exception of some cleaners, controls, heat pumps and electronic chlorinators, are 17 digits long and begin with the numbers '21'. Often these numbers appear on product labels with spaces or parentheses., Here you’ll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place. ... iPad Heater Navigation - OmniLogic Automation System. iPhone Favorites - OmniLogic ..., 1. First, check that your filter pump is On. Next, ensure the heater is enabled and the set point is higher than the current water temperature. Select the bow to water. Press the heater tile to enter the heater's menu. 2. Ensure the heater is enabled and the set point is higher than the current water temperature., This code indicates. the switch opened during the heating cycle. I followed the instructions to cycle back to standby and then back to pool mode and immediately …, Hayward-error-codes - Free download as PDF File (.pdf), Text File (.txt) or read online for free. The document provides troubleshooting information for Hayward pool ..., Answering a viewers request on how to add and program a newly installed heater to a Hayward OmniLogic Automation system., Hayward® is America's first choice for residential and commercial swimming pool and spa equipment. We manufacture the Totally Hayward™ System and sell our products direct to wholesalers. ... Pump, Filter, Heater, Lights, & Whole Goods Tech Support. 1 (908) 355-7995 (U.S.) Contact us by letter: Hayward Holdings, Inc. 1415 Vantage Park Drive ..., Learn How Solar Pool Heaters Work; Learn About Hayward. At Hayward, we're more than just equipment. Learn more. Hayward Insights. Hayward Insights. Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support., The document provides troubleshooting information for Hayward pool heaters, including: 1. Error codes and their meanings to help diagnose issues, such as a blocked ..., Available in 150,000, 200,000, 250, 000, and 400,000 BTUs, the Universal H-Series heater can raise the temperature of an 800-gallon pool 30 degrees in less than an hour—you'll feel the benefits the moment you step into the water. The Hayward Universal H-Series Low NOx can be added to inground pool kits sold by Pool Warehouse!, Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools., Hayward H250FDN ERROR CODE Sb. Chilo1971. Jan 11, 2020. Jump to latest Follow Reply. Forums. News and Announcements. About Trouble Free Pool. C., The hayward pool heater h5 code is designed to effectively address gas supply problems, ensuring optimal performance and uninterrupted pool heating. With its advanced technology and reliable functionality, it ensures a seamless and hassle-free pool heating experience., According to the H-Series pool heater owner's manual by Hayward, cleaning your heater filters is one of the most important steps you can take. That is to say, regularly cleaning these filters will lead to a longer lasting and better working pool heater. 1. Remove Filter Cover or Gain Access., When your Hayward pool heater flashes the 'bo code', it's signaling that there's an issue with the bypass operation. Here's a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the 'bo code' persists., Use the “Mode” key to change your heater’s settings. Select the “Standby” Option and put the heater on it. Press the remote’s “Down” key and hold it and then press the Mode key and hold it simultaneously. For 3 seconds, hold down both the “Down” and “Mode” keys as long as the “bo” code doesn’t remove from your ..., SPECIFICATIONS AND DIMENSIONS H500FD H400FD H250FD H200FD H150FD BTU/hr 500,000 399,900 250,000 199,900 150,000 Thermal efficiency 83% 84% 84% 83% 82.7%, Many utilities and energy efficiency service providers offer rebates to pool owners who purchase energy-efficient pool equipment such as Hayward's ENERGY STAR Certified pool pumps. You may be eligible for a rebate if you purchase one of Hayward's energy-efficient variable-speed pumps. For more information, check with your local utility ..., Hayward pool heater if code. If your Hayward pool heater displays an IF or 1F code, it indicates an issue of "Ignition Failure" in your pool heater. Different problematic components trigger the code to appear on display. Well, showing code helps you to determine a specific issue and helps you to take steps to the relevant issue immediately., Common Causes of the H5 Code. When your pool heater displays the H5 code, it typically occurs due to a few common reasons. Troubleshooting h5 code in other pool equipment can help identify the issue. Common misconceptions about h5 code in Hayward pool heaters include thinking it is solely related to a faulty igniter or gas valve., Step 1. Turn off the power supply to the pool heater. Step 2. Wait for at least five minutes to allow the heater to cool down. Step 3. Turn the power back on and press the reset button. This button is typically located near the heater’s control panel or on the heater’s interior., The tech did the install and ran the heater only for a few minutes to check for ignition and stuff. He had done some other plumbing work so he didn't want to run in too long, or the pool pump either, so that the PVC glue really had some time to cure. The heater is a 400,000 BTU Hayward Universal HC Series Model HDF400 Pool Heater., Carefully check over the pump impeller, diffuser, shaft seal, and motor for problems or signs of damage, and replace parts as necessary. Verify motor connections to the drive. Heatsink Overheated. The heatsink of the drive has overheated. Make sure that the vents on the motor are clear of debris and obstructions., What Is Hayward Pool Heater Code Ce And Why Is It Important? Hayward pool heater code ce is an important safety measure for pool owners. It ensures that the heater meets the necessary european standards and regulations, guaranteeing efficient and safe operation. Importance Of Complying With Code Ce Standards, Apr 22, 2023 ... I fixed Lo error! hayward spa heater was giving me a LO error when ... FALLA IF EN CALENTADOR HAYWARD ... Hayward 250H Pool Heater LO code. Rob ..., Hayward H250FDP pool heater showed SF code. Replaced the thermistor and restarted the power. Display still shows SF code and sevice light on. Cycled the mode button and the blower comes on, ..., Hayward H-Series H200FD pool heater has 200,000 BTUs equipped with user friendly electronic ignition and capabilities for natural gas and propane. Call Us Nationwide: 1-800-741-9956. ... CODE: ERN152A-8009 / ERLP152A-8009 $ 2,995.00. Raypak R2450ti-E Pool Heat Pump, 48,000 BTU. CODE: R2450ti E Compact $ 2,999.00. Connect With Us. Facebook ..., Check the Gas Valve. Start by ensuring that the gas valve is open and allowing the flow of gas to the pool heater. If the gas valve is closed or partially closed, the heater won’t receive the necessary fuel to ignite. Make sure the valve is fully open and functioning correctly., We have a older Hayward heater that needs something because we have a older Hayward heater that needs something because our pool is small 16 x 28 and it takes a good 6 hours to heat. Live in Henderson NV do we need a new element or can you recommend someone.