Suction pressure for 410a

the heat content of the return air (including the sensible temperature) drops, the saturated suction temperature will drop, resulting in a drop in suction pressure. As the suction pressure falls to 120psig the APR Control will begin to open and attempt to stabilize the system suction pressure at approximately 120psig.

Suction pressure for 410a. Many women decide to live child-free. Yet, they often feel they owe everyone an explanation about a choice that should be entirely personal. OUR BRANDS

In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...

Continue the process until the system has been determined to be leak-free. Connect the vapor-line and liquid-line pressure taps to a vacuum pump and micron meter. This step is also almost always omitted. Evacuate the refrigerant lines and indoor coil to at least 350 microns. Close off the valve to the vacuum pump and observe the micron meter.Weather forecasters can tell what the weather will be by reading the barometric pressure, but how does it work? Advertisement You've probably experienced the scenario where, on a c...What would be the approximate refrigerant pressure of an R-410A machine at (80°F) room temperature while that machine is idle? A. 143 PSIG B. 212 PSIG C. 238 PSIG D. 260 PSIG and more. ... Lower suction pressure B. Higher suction pressure C. Lower discharge pressure D. Higher discharge pressure. D. Higher discharge pressure. 59. What is the ...• Protected compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high and low pressure …These line sizing charts are based on a suction pressure drop equivalent to a 2°F change in saturation pressure and liquid line pressure drop of 5 psi. For R-404A Low Temperature 1 psi; for R-404A and R-22 Medium Temperature 2 psi is used. This is the maximum allowable pressure drop for the entire piping run regardless if it is 50' or 250'.In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the...Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and continue increasing the pressure on both sides almost to 400psi on ...

These liquid-line restrictions all cause the evaporator, compressor, and condenser to be starved of refrigerant. This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control;Gonzo, if your evap was dirty you would have a low suction and low superheat. Not dirty evap let that go. High suction low head, with 100 lb suc and 100 degree ambient your head should be quite a bit higher. Really need the amp draw of comp and rated RLA but appears to be a compressor issue. The higher pressure, and the fact that R-410A performs very much like a single component refrigerant, provide an opportunity to produce a more compact system with greater efficiency. In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses. The higher pressure, and the fact that R-410A performs very much like a single component refrigerant, provide an opportunity to produce a more compact system with greater efficiency. In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses.(R-32/125) (50 / 50 wt%) Replaces: R-22. Applications: Air conditioning equipment and heat pumps. Only for newly manufactured equipment, not for retrofitting R-22 systems. …

With 410a heat pumps is there a recommended suction pressure. For example with R22 air-con systems I always aim for 400 suction and 1500 discharge and similar with 407c systems. I have been told to aim for round the 100 psi/700kpa mark with is about 0 degree C Was just curious for fault finding purposes. Cheers in advance, chris.Technical Guide: R-410A Outdoor Split- System Heat Pump - RHP143. York International Corporation, 5005 York Drive, Norman, OK 73069. 2022-10-05 6231804-UTG-A-1022 Supersedes: nothing. 2 Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 Johnson Controls Ducted Systems.Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems.Names Ron & I am an HVAC contractor with 20 yrs experience and I have hit a wall. I have installed a new Rheem 410A system that has a fluctuating suction pressure from 115 - 130 approx. System has a new 410A piston coil. I could not replace the line set and had to flush. I installed new filter dryer. Installed by the book, flow nitro and …SUCTION PRESSURE / EVAP DTD RULE OF THUMB Another common old school rule of thumb is suction pressure should be close to the outdoor temperature in a R-22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient.

Aldi milledgeville ga.

Some people have low blood pressure (hypotension). It is only a problem if it causes dizziness, fainting, or shock. Learn about what can cause it. You've probably heard that high b...Aug 5, 2023 · Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so. There's no shortage of cable management options, but often times you need to employ a few different options in order to keep yours neat, tidy, and accessible. When you want to add ... Constants for vapor pressure of saturated vapor (dew point), p g: A = –1.440004 E+00 E = –3.521484 E+00 B = –6.865265 E+00 F = –7.750000 E+00 C = –5.354309 E–01 X o = 2.086902 E–01 D = –3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ...

As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of ...Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F.Jun 24, 2020 · We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. Oct 12, 2018 ... ... suction pressure is low. When technicians see low suction pressure, many of them may add charge and then realize that the TXV throttles down ...This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.Temperature (°F): R410A Pressure (psig): -60 °F. 0.9 psig. -55 °F. 1.8 psig. -50 °F. 4.3 psig.Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is _____ than R22, Both suction and discharge pressures of R-410A systems are _____ than R-22 systems, The temperature glide for R-410A is less than _____ degrees Fahrenheit over air conditioning and refrigerating operating ranges and more.Sep 18, 2020 · The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits. The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.Jan 3, 2014 · Currently working on a Bremar ice maker. Just did a compressor change and thought I weigh charged it perfectly. But it's not making good ice. I have only a suction port to read the pressures, and I'm getting 300kpa at the beginning of the 8.5 min cycle, and around 240kpa by the end. It runs for 8.5miutes then goes on defrost to drop the ice made. R-410A Pressure-temperature chart Click anywhere on this document to return to Refrigerant Gas Properties information at InspectApedia.com This chart was provided by the Bonneville Power Authority,

what would cause the high side and low side pressure on a r410a 3 ton goodman heat pump to be 400+ psi? The unit was charged in heating mode and 11lbs 1 oz of refrigerant was used. ... high suction pressure 130 plus low discharge pressure 150. No heat outside coil freezes maybe a bad compressor.

R410A Pressure Temperature Chart R410A Temperature (°C) Pressure (barA) Pressure (barg) Pressure (psig) Pressure (barA) Pressure (barg) Pressure (psig)-70 0.36 -0.66 -9.52 0.35 -0.66 -9.55-68 0.40 -0.61 -8.85 0.40 -0.61 -8.87-66 0.45 -0.56 -8.10 0.45 -0.56 -8.13-64 0.51 -0.50 -7.27 0.51 -0.50 -7.31-62 0.57 -0.44 -6.37 0.57 -0.44 -6.40Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, …Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ...R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ... Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU. Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ... Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Charge (limit) lbs 13 13 13 17 17 17 17 Oil Type Trane OIL00079 (qt)/OIL00080 (gal) Oil Charge oz 101 101 101 88 112 112 112 Suction Fitting Connection Brazed Brazed Brazed Brazed Brazed Brazed Brazed Suction Fitting (ODF) in 1.125 1.125 1.125 1.375 1.375 1.375 1.375 Low-side air conditioner compressor motor pressure: This is the pressure in the air conditioner's refrigerant suction line (low side pressure during compressor operation) and this will be a relatively low number, often less than 100 psi. During operation, refrigerant is returning to the compressor from the cooling (evaporator) coil in this line.

Nba playoffs magic number.

Red lobster butler pa.

410a ductless mini split operating pressures. I know that you should rarely put gauges on a ductless mini split, and that you should dump the charge and just weigh it in. I have heard that there are spec sheets that will give you "normal operating pressures" based on indoor and outdoor conditions. This would come in handy when servicing systems ...OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock out compressor, run air handler fan only.psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, …Sep 19, 2013 ... This one covers a test of an air conditioner with high return air temperature to determine how high the suction pressure will go.psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi. Why this ...r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3Jul 27, 2012 ... Comments2 ; Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips! AC Service Tech LLC · 1.2M views ; What Should my AC ...pressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), andContinue the process until the system has been determined to be leak-free. Connect the vapor-line and liquid-line pressure taps to a vacuum pump and micron meter. This step is also almost always omitted. Evacuate the refrigerant lines and indoor coil to at least 350 microns. Close off the valve to the vacuum pump and observe the micron meter. ….

This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.What is the r410a’s standing pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. What is the best 410a ...Anon The compressor is running and producing no pressure it's possible that it's because you've lost the refrigerant charge from the system. On 2020-06-14 - by (mod) - Possibly a jammed TEV. On 2020-06-13 by Clay what causes high pressure on the suction line on Rheem R410a ? On 2020-06-11 by AnonymousOperating an air conditioner for extended periods of time in low temperatures outdoors lowers the suction pressure to a velocity where the oil will not return to the compressor and will run dry. Also, under low ambient conditions “indoors” does not provide sufficient load to change refrigerant from a liquid to a 100% vapor.The fuel-injection system in a Toyota truck requires a specific fuel pressure at all times or else the engine will not run correctly. If your Toyota's idle is dropping or you think... psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114 My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2.SUBJECT: TEMPERATURE - PRESSURE CHART FOR FYI #289 9/17/2009 R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS ADVANTAGE Engineering, Inc.525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 web site: www.AdvantageEngineering.com email: [email protected] Suction pressure for 410a, This would typically cause a low suction pressure, and a low superheat. In heat mode, a dirty air filter causes low airflow across the condenser. ... this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient. This means if it is 50˚ outside the suction ..., Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C), R-410A Pressure-temperature chart Click anywhere on this document to return to Refrigerant Gas Properties information at InspectApedia.com This chart was provided by the Bonneville Power Authority,, Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the components that make up Freon™ 407C and Freon™ 410A. Table 1. Components of Freon™ 407C: HFC-32/HFC-125/HFC-134a and Freon™ 410A: HFC-32/HFC-125, 3. R-410A compatibility offered with P266SNR-2C transducer PRODUCT SWITCH ACTION BOTTOM OF RANGE TOP OF RANGE MAXIMUM WORKING PRESSURE TYPICAL APPLICATIONS P70 SERIES ADJUSTABLE ON/OFF PRESSURE CONTROLS P70AA-2C SPST Open Low 0 150 325 Suction pressure control — loss of charge P70AA-400C SPST Open Low 100 470 690 Fan cycling for head pressure ..., By contacting an HVAC technician, you can get your AC system’s suction pressure back to normal levels. If you are experiencing a problem with your air conditioning or heating call us at 512-336-1431 to schedule an appointment. We’ll be glad to come out and take a look at the issue. 1431-183 A/C & Heating proudly serves Round Rock ..., Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the components that make up Freon™ 407C and Freon™ 410A. Table 1. Components of Freon™ 407C: HFC-32/HFC-125/HFC-134a and Freon™ 410A: HFC-32/HFC-125, ™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems ... Suction Pressure, kPa (psia) 104 (15) 138 (20) Discharge Pressure 1484 (215) 1470 (213) Discharge Temperature 128 (263) 92 (197), Liposuction is the removal of excess body fat by suction using special surgical equipment. A plastic surgeon typically does the surgery. Liposuction is the removal of excess body f..., How to Use a Pool Vacuum. Visit HowStuffWorks.com to learn more about how to use a pool vacuum. Advertisement Using a pool vacuum makes the task of cleaning the floor of the pool e..., Continue the process until the system has been determined to be leak-free. Connect the vapor-line and liquid-line pressure taps to a vacuum pump and micron meter. This step is also almost always omitted. Evacuate the refrigerant lines and indoor coil to at least 350 microns. Close off the valve to the vacuum pump and observe the micron meter., “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 …, Jul 27, 2012 ... Comments2 ; Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips! AC Service Tech LLC · 1.2M views ; What Should my AC ..., On a properly functioning R-22 system running in heat mode in 40-degree weather, the suction pressure tends to be around 40 PSIG. This guideline obviously doesn't work on an R-410A system or any other refrigerant. A more applicable guideline is 20-25˚ suction saturation below outdoor ambient temperature., No, the same line sizes used for R-22 are used for R-410A. The ideal line size for R-410A is smaller in diameter than R-22 tubing and falls between the standard available nominal refrigerant tubing sizes. The same tubing sizes used for R-22 must be used for R-410A to avoid excessive pressure drops when using the next smaller tube., The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ..., Both suction and discharge pressure of R-410a systems are _____ than R-22 systems. Lower. Because of its higher vapor capacity, the discharge temperature of R-410a is _____ than R-22. 610 psig plus or minus 10psig. R-410a systems use a high pressure switch that will open at approximately: lose or gain., The upright vacuum cleaner remains the standard, with great suction power. Here are the best upright vacuums from Dyson, Shark and others. By clicking "TRY IT", I agree to receive ..., Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ..., The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi. Vapor pressure: 295.5 psi. See all other pressures for R410 on …, Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Charge (limit) lbs 13 13 13 17 17 17 17 Oil Type Trane OIL00079 (qt)/OIL00080 (gal) Oil Charge oz 101 101 101 88 112 112 112 Suction Fitting Connection Brazed Brazed Brazed Brazed Brazed Brazed Brazed Suction Fitting (ODF) in 1.125 1.125 1.125 1.375 1.375 …, Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity., Bags are hard to remove from garbage cans because of a vacuum that forms — until now. Expert Advice On Improving Your Home Videos Latest View All Guides Latest View All Radio Show ..., R410A. R454B. Refrigeration Equipment. Air Cooled Condensers. Chillers. Condensing Units. Cooling Towers. Fluid Coolers. Ice Machines & Parts. Refrigerators & Freezers. ... Pressure/Temperature Chart. Temperature (F) R-22 R-410A R-12 R-134a R-404A R-507A R-407A R-407C R-427A R-422B R-422D R-407F R-448A R-421A R-513A R-449A R …, I am a new tech in training and have a problem at my own house. My 410a system keeps freezing up. Filter is new. suction pressure is about 85 which seems low and head pressure is about 230 which seems ok. Super heat goes all over the place from 6 to 16. do you think I have a refrigerant restriction? Any help is greatly appreciated. Thanks., An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems., – Freon™ 410A is for new equipment that is specifically designed for R-410A. • Freon™ 410A will require use of manifold gauge sets, recovery machines, and recovery tanks specifically designed for higher pressures encountered with R-410A. Saturation Pressure (psig): R-22 vs. R-410A AC System Considerations, What is r410a’s suction pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Related Articles:, What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system., What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system., 410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or evaporator or condenser ..., Hence, R410A refrigerant is considered safer than R22 refrigerant which is why it is a direct replacement for R22 refrigerant despite being slightly higher in GWP. R410A refrigerant is also a high-pressure refrigerant. The suction pressure of R410A air conditioners is usually around 125 psi (862 kPa) which is much higher than R22 air …, In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...